WDS 1U4PGE GEPON OLT 4port (part no: WDS1U4PGE) – WEB + CLI + SNMP management !
Wodaplug Pizza-Box OLT series products is 1U high 19 inch rack mount product. The features of the OLT are small, convenient, flexible, easy to deploy, high performance. It is appropriate to deploy in an compact room environment.
The OLT can use for “Triple-Play”, CPN, IP Camera, Enterprise LAN and IOT applications. It is a high performance products. Our products use the best – CORTINA CS8032 Chipset !
Wodaplug WDS1U4PGE provides 4GE and 4 SFP slots interface for uplink, and 4 EPON ports for downstream. It can support 256 ONU under 1:64 splitter ratio.Passive Optical Network ( PON , Passive Optical Network ) consists of an optical line termination ( Optical Line Termination , OLT) at the central side of the network to which is attached a branched structure of optical splitters – splitters . These are connected end optical network unit ( Optical Network Unit , ONU ), most often in a tree , or ring or star topologies . The distance between the OLT and ONU can be up to 20 km .
EPON OLT units WDS1U4PGE are equipped by well known brand chipset Cortina CS8032, therefor wodaplug power and signal level is very high and provide for your future network fast stable connection. Heat rezistence was tested in long time period in real setups and its very good even in temperatures over 40C. Wodaplug OLT units are equiped with redudant dual powersources, which is very important for reliable non breaking usage!!
Wodaplug Pizza-Box OLT serie is standard sizing for 1U 19″ „rack mount“. Advantages are simple: compact size, easy instalation, management, flexibility and power output.
Wodpalug OLT are very good when used for “Triple-Play” applications, CPN, IP kamery, Enterprise LAN networks and IOT apps. Its possible thanks to using newest – CORTINA CS8032 Chipset !
Wodaplug FD1104SN offers 4GE a 4 SFP slots – interface for uplink, and 4 EPON ports for downstream. Supports up to 256 (4*64) ONU in 1:64 splits PLC by passive wodaplug splitters .
Optical netwok behave transparently as smart switch, VLAN can be configured for each port of end ONU units. Configuration of ONU is easy thanks to preconfigured templates ( 4 and 8 ports OLT units has template management in base version ! ! ) Newly connected ONU unit automaticly downloads configuration from previosely set template (provisioning). Configuration OLT unit is possible via WEB management or 1. thru supplied EMS configuration software – central management ) based on SNMP (needs mySQL and reqiure additional SW instalation on master managing PC) or 2. by telnet and CLI (standard command line interface). Wodaplug units supports SNMP (mibs) protocol.
- Support 4 PON ports at most.
- Support 256 ONU (by 1:64 splitting ratio within 10km).
- provides 4GE(copper) and 4SFP slots Combo interface for uplink.
- Layer-two link rate switch.
- MAC Address Capacity: 16K
- VLAN supported number:4096
- ONU auto-detection and registration
- Dynamic bandwidth allocation.
- Support online upgrading and ONU batch upgrade.
- Management Interface: Support in-band and out-band management.
- Management Mode: WEB, CLI, TELNET
Wodaplug 4 and 8 port OLT support templates, so you can configure ONUs based on template management (provisioning)!
Easy configuration using EMS (mySQL and SNMP based) central management system and standard CLI command line interface!
Dual 220V Power Supply – two redundant PSUs !!
The FD1104SN 1U high Pizza-Box, can be mounted into the standard 19” rack. Demission of machine frame: 390 mm (Length) x 250 mm (Width) x 44 mm (Height).
Wodaplug WDS1U4PGE EPON has 4 EPON SFP ports, 4GE(copper) and 4SFP slots Combo interface for uplink, 1 console port and 1 GE network management port.
SPECIFICATIONS
Item | WDS1U4PGE | WDS1U8PGE | ||
Chassis | Rack | 1U 19 inch standard box | 1U 19 inch standard box | |
Slots | NA | NA | ||
Uplink Port | QTY | 8 | 16 | |
Copper | 10/100/1000M auto-negotiable,RJ45:8pcs | 10/100/1000M auto-negotiable,RJ45:8pcs | ||
SFP | 4 SFP slots(Combo) | 8SFP slots(Combo) | ||
PON Port | QTY | 4 | 8 | |
Physical Interface | SFP Slots | SFP Slots | ||
Connector Type | 1000BASE-PX20+ | 1000BASE-PX20+ | ||
Max splitting ratio | 1:64 | 1:64 | ||
Management Ports | 1*100BASE-TX out band port
1CONSOLE port |
|||
PON Port Specification
(Apply to C-Data PON module) |
Transmission Distance | 20KM | ||
PON port speed | Symmetrical 1.25Gbps | |||
Wavelength | 1490nm TX,1310nm RX | |||
Connector | SC/PC | |||
Fiber Type | 9/125μm SMF | |||
TX Power | +2~+7dBm | |||
Rx Sensitivity | -27dBm | |||
Saturation Optical Power | -6dBm | |||
Management Mode | SNMP, Telnet, CLI management mode. | |||
Management Function | Fan Group Detecting
Port Status monitoring and configuration management; Layer-2 switch configuration such as Vlan, Trunk ,RSTP,IGMP ,QOS, etc; EPON management function: ONU authorization, ACL ,QOS ,etc; Online ONU configuration and management User management Alarm management |
|||
Layer-two Switch | Support port VLan and protocol Vlan
Support Vlan tag/Untag ,vlan transparent transmission; Support 4096 VLAN Support 802.3dd trunk RSTP QOS based on port ,VID,TOS and MAC address IGMP Snooping 802.x flow control Port stability statistic and monitoring |
|||
EPON Function | Support port-based rate limitation and bandwidth control;
In compliant with IEEE802.3ah Standard Up to 20KM transmission Distance Support data encryption, group broadcasting, port Vlan separation , RSTP, etc. Support Dynamic Bandwidth Allocation (DBA) Support ONU auto-discovery/Link detection/remote upgrade of software; Support VLAN division and user separation to avoid broadcast storm; Support various LLID configuration and single LLID configuration .Different user and different service could provide different QoS by means of different LLID channels. Support power-off alarm function ,easy for link problem detection Support broadcasting storm resistance function Support port isolation between different ports Support ACL and SNMP to configure data packet filter flexibly Specialized design for system breakdown prevention to maintain stable system Support dynamic distance calculation on EMS online Support RSTP,IGMP Proxy |
|||
Dimension | 440*280*44(mm*mm*mm) | |||
Weight | 4.2kg | 4.5kg | ||
Power Supply | 220VAC | AC: oct 24, 2014 – 90V~240V,47/63Hz | ||
-48DC | DC:-36V~-72V | |||
Power Consumption | 30W | 45W | ||
Operating Environment | Working Temperature | 0~50℃ | ||
Storage Temperature | -40~85℃ | |||
Relative Humidity | 5~90%(non-condensing) |
Wodaplug OLT series products is 1U high 19 inch rack mount product. The features of the OLT are small, convenient, flexible, easy to deploy, high performance. It is appropriate to deploy in an compact room environment.
The OLT can use for “Triple-Play”, CPN, IP Camera, Enterprise LAN and IOT applications. It is a high cost performance products.
WDS1U4PGE 4PON Ports 1U OLT
WDS1U4PGE provides 4GE(copper)and 4SFP slots Combo interface for uplink, and 4 EPON ports for downstream. It can support 256 ONU under 1:64 splitter ratio.
WDS1U8PGE 8PON Ports 1U OLT
WDS1U8PGE provides 8GE(copper)and 8SFP slots Combo interface for uplink, and 8 EPON ports for downstream. It can support 256 ONU under 1:64 splitter ratio.
Specifications
Item | WDS1U4PGE | WDS1U8PGE | ||
Chassis | Rack | 1U 19 inch standard box | 1U 19 inch standard box | |
Slots | NA | NA | ||
Uplink Port | QTY | 8 | 16 | |
Copper | 10/100/1000M auto-negotiable,RJ45:8pcs | 10/100/1000M auto-negotiable,RJ45:8pcs | ||
SFP | 4 SFP slots(Combo) | 8SFP slots(Combo) | ||
PON Port | QTY | 4 | 8 | |
Physical Interface | SFP Slots | SFP Slots | ||
Connector Type | 1000BASE-PX20+ | 1000BASE-PX20+ | ||
Max splitting ratio | 1:64 | 1:64 | ||
Management Ports | 1*100BASE-TX out band port
1CONSOLE port |
|||
PON Port Specification
(Apply to C-Data PON module) |
Transmission Distance | 20KM | ||
PON port speed | Symmetrical 1.25Gbps | |||
Wavelength | 1490nm TX,1310nm RX | |||
Connector | SC/PC | |||
Fiber Type | 9/125μm SMF | |||
TX Power | +2~+7dBm | |||
Rx Sensitivity | -27dBm | |||
Saturation Optical Power | -6dBm | |||
Management Mode | SNMP, Telnet, CLI management mode. | |||
Management Function | Fan Group Detecting
Port Status monitoring and configuration management; Layer-2 switch configuration such as Vlan, Trunk ,RSTP,IGMP ,QOS, etc; EPON management function: DBA ,ONU authorization, ACL ,QOS ,etc; Online ONU configuration and management User management Alarm management |
|||
Layer-two Switch | Support port VLan and protocol Vlan
Support Vlan tag/Untag ,vlan transparent transmission; Support 4096 VLAN Support 802.3dd trunk RSTP QOS based on port ,VID,TOS and MAC address IGMP Snooping 802.x flow control Port stability statistic and monitoring |
|||
EPON Function | Support port-based rate limitation and bandwidth control;
In compliant with IEEE802.3ah Standard Up to 20KM transmission Distance Support data encryption, group broadcasting, port Vlan separation , RSTP, etc. Support Dynamic Bandwidth Allocation (DBA) Support ONU auto-discovery/Link detection/remote upgrade of software; Support VLAN division and user separation to avoid broadcast storm; Support various LLID configuration and single LLID configuration .Different user and different service could provide different QoS by means of different LLID channels. Support power-off alarm function ,easy for link problem detection Support broadcasting storm resistance function Support port isolation between different ports Support ACL and SNMP to configure data packet filter flexibly Specialized design for system breakdown prevention to maintain stable system Support dynamic distance calculation on EMS online Support RSTP,IGMP Proxy |
|||
Dimension | 440*280*44(mm*mm*mm) | |||
Weight | 4.2kg | 4.5kg | ||
Power Supply | 220VAC | AC: 90V~240V,47/63Hz | ||
-48DC | DC:-36V~-72V | |||
Power Consumption | 30W | 45W | ||
Operating Environment | Working Temperature | 0~50℃ | ||
Storage Temperature | -40~85℃ | |||
Relative Humidity | 5~90%(non-condensing) | |||